end suction mining submersible pump for deep well

end suction mining submersible pump for deep well
Product Detailed
mining submersible pump for deep well 1.copper wire winding 2.copper end ring 3.one year warranty 4.casting,SS available

end suction mining submersible pump for deep well

  

Operation parameters :

  Flow range : 10-500 m3/h

  Lift range : 10-600m

Material

Impeller:Cast iron HT200,or tin bronze,such as ZCuSn3Zn8Pb6Ni1

Pump bowl:Cast iron HT200,or stainless steel,such as 2Gr13.304

Pump shaft :Cold-drawn steel with chrome plating,or stainless steel 2Gr13(1050 thermal refining ,enhancent torsional moment)

Motor Seal:Rubber O-ring seal,mechanical seal

Motor regulating sleeve:rubber.

Product overview :

Self-cool high-lift downdraft pump adopt wet water-filled submersible   motor, cavity as the water channel between motor shell and the retaining barrel can make the motor fully cool and let the submersible pump have the characteristics of good thermal condition , long life , high efficiency, simple structure and low cost.

National patent , retaining barrel , downdraft , high power, high flow, high-lift pump, downdraft pump is designed for mine underground rescue drainage as water-carrying tool, and it can completely drain the mine water and have the characteristic of rational structure , high efficiency and low energy , convenient installation and maintenance, reliable using.

 QJ using condition 

  1. 380V voltage deviation is no more than ±5%,frequency is 50HZ, three -phase power deviation is no more than ±1%.

  2 . Motor cavity must be filled with water.

  3.The first stage impeller of the pump should be more than 2mm below the moving water surface, pump unit should be no more than 70m below the static water level.

  4. The distance from the motor bottom to well bottom must be more than 3m.

  5. Water temperature should be no more than 20°C.

  6 .Sand content of the water ( by mass) should be no more than 0.01%.

 7. PH value of water is 6.5-8.5.

8. Hydrogen sulfide (H2S) content of the water should be no more than 1.5mg/L.

 9. Chloride ion content of the water should be no more than 400mg/L.

 10. Water yield of water source should ensure the requirements of the pump’s continuous working.

  



Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.